American Gage logo

Calibration Service

Pipette Calibration in Orange County & Los Angeles

Southern California’s biotech and medical device labs run on pipettes — and on the calibration data behind them. American Gage calibrates single- and multi-channel pipettes to ISO 8655 under A2LA ISO/IEC 17025 accreditation, with free pickup routes through Orange County (Mon & Wed) and LA County (Tue & Thu).

Photometric pipette calibration station in the American Gage life science laboratory

Method

Gravimetric & photometric (ISO 8655)

Service levels

2×4 standard → 3×10 accredited

Uncertainty methodology

ISO 8655-7

Accreditation

A2LA ISO/IEC 17025:2017 · #4296.01

Gravimetric and photometric — matched to your compliance level

Both ISO 8655 methods are available in our environmentally controlled life-science lab: gravimetric verification on analytical balances, and dye-based photometric verification for low volumes and multi-channel heads. Service levels scale with your quality system — from a standard 2×4 As Found / As Left verification up to fully accredited 3×10 / 3×10 data with measurement uncertainty per ISO 8655-7.

For GMP, ISO 13485, and CLIA-adjacent environments, certificates document as-found/as-left readings at each test volume, uncertainty, environmental conditions, and NIST traceability — the package your auditors expect to trace.

Built for lab logistics

Pipettes shouldn’t sit in a courier network for two weeks. Our own drivers collect through Orange County every Monday and Wednesday and Los Angeles County every Tuesday and Thursday — free — with standard 7–10 business day turnaround and expedited options. Preventive maintenance and repair (seals, o-rings, pistons) can be handled on the same service, so instruments come back both accurate and healthy.

What we see most

  • Single-channel pipettes (fixed & adjustable)
  • Multi-channel pipettes (8/12-channel)
  • Electronic / motorized pipettes
  • Repeaters & dispensers
  • Bottle-top dispensers
  • Burettes

Pipette Calibration FAQs

How often should pipettes be calibrated?

Most GMP and ISO 13485 quality systems verify pipettes every 3–12 months depending on usage and criticality; many high-throughput labs add quick interim checks. We calibrate to your SOP’s interval and can recommend one based on as-found history.

Do you offer accredited pipette calibration with data?

Yes — up to 3×10 / 3×10 accredited service under our A2LA ISO/IEC 17025:2017 accreditation, with uncertainty calculated per ISO 8655-7 on every test volume.

Can you service pipettes as well as calibrate them?

Yes — preventive maintenance and repair are available on the same visit, so out-of-tolerance pipettes can be repaired, re-calibrated, and returned in one cycle.

Need pipette calibration?

Send your list — manufacturer, model, quantity — and we'll return scope, pricing, and turnaround within one to two business days.