American Gage logo

Calibration Service

Multimeter Calibration in Orange County

From the handheld Fluke on a maintenance cart to 8.5-digit bench DMMs, American Gage calibrates multimeters with automated Fluke MET/CAL procedures — uncertainty calculated at every point, firmware-level adjustment where supported.

DC voltage calibration of a Fluke 8845A precision multimeter at American Gage

Automation

Fluke MET/CAL procedures

Reference DMMs

up to 8.5 digits

Turnaround

7–10 business days (expedited available)

Accreditation

A2LA ISO/IEC 17025:2017 · #4296.01

Automated procedures, not spot checks

Our electrical laboratory runs the Fluke MET/CAL automated calibration system with a current procedure subscription. For multimeters that means every function and range gets exercised per the manufacturer’s procedure — DC/AC voltage, current, resistance, frequency — with measurement uncertainty computed at each test point and adjustments performed at firmware level where the instrument supports it.

Certificates document as-found/as-left readings across functions, uncertainty, NIST traceability, and the Z540.3 decision rule with TUR — the record an auditor can actually follow.

Fleet-friendly logistics

Maintenance departments send DMMs by the case: free pickup routes run through Orange County Monday and Wednesday, LA County Tuesday and Thursday, and the Inland Empire Friday, with 7–10 business day standard turnaround. Handhelds, bench meters, clamp meters, and insulation testers ride the same cycle — and on-site electrical calibration is available when the fleet can’t leave.

What we see most

  • Handheld digital multimeters
  • Bench DMMs (6.5 & 8.5 digit)
  • Clamp meters
  • Insulation testers / meggers
  • Analog multimeters
  • Process meters & loop calibrators

Multimeter Calibration FAQs

How often should a multimeter be calibrated?

Manufacturers typically specify 12 months; many quality systems match that, tightening to 6 months for meters used in critical measurements. We calibrate to your interval and report as-found data so you can tune it.

Do you calibrate all multimeter brands?

Yes — Fluke, Keysight/Agilent, Tektronix, BK Precision, Extech, and most others, using manufacturer procedures through MET/CAL where available.

Can you adjust an out-of-tolerance meter, not just report it?

Yes — where the instrument supports adjustment, we adjust at firmware level and document both as-found and as-left readings on the certificate.

Need multimeter calibration?

Send your list — manufacturer, model, quantity — and we'll return scope, pricing, and turnaround within one to two business days.